NVIDIA HGX B200 Specs & Datasheet (8-GPU Node)
TL;DR
The NVIDIA HGX B200 is an 8-GPU Blackwell node: eight B200 GPUs with 180 GB of HBM3e each — 1,440 GB per node — connected over a fifth-generation NVLink baseboard, with roughly 64 TB/s of aggregate memory bandwidth for large-model training and inference. It ships factory-integrated from several OEMs (Lenovo, Dell, Supermicro, Gigabyte) in air- or liquid-cooled form factors; configuration, power, and pricing are confirmed at quote.
On this page
What the HGX B200 is
The HGX B200 is NVIDIA’s 8-GPU Blackwell server platform — the current mainstream data-center node for large-model training and high-throughput inference. Eight HGX B200 GPUs sit on a single fifth-generation NVLink baseboard, so the node behaves as one tightly-coupled 8-GPU accelerator rather than eight discrete cards.
Unlike a rack-scale system such as the GB300 NVL72, the HGX B200 is a node you rack in a standard data center: a single 4U–10U chassis (depending on integrator and cooling) that drops into a conventional rack. It is the Blackwell successor to the Hopper HGX H100/H200 8-GPU nodes, and it is offered by multiple OEMs in both air- and liquid-cooled builds.
Full spec sheet
The HGX B200 8-GPU node specification, aggregated from the current integrator builds (Lenovo, Dell, Supermicro, Gigabyte). The per-GPU and per-node GPU, memory, and NVLink figures below are fixed characteristics of the platform; chassis, CPU, cooling, site power draw, and final configuration vary by integrator and are confirmed at quote.
| Spec | HGX B200 (8-GPU node) |
|---|---|
| GPU architecture | NVIDIA B200 · Blackwell |
| GPUs per node | 8× HGX B200 |
| HBM3e per GPU | 180 GB |
| HBM3e per node | 1,440 GB |
| Memory bandwidth | ~8 TB/s per GPU · ~64 TB/s aggregate |
| Peak FP8 (dense) | ~4.5 PFLOPS FP8 · ~9 PFLOPS FP4 per GPU (~36 / ~72 PFLOPS per node, derived) |
| NVLink | 5th-gen · 1.8 TB/s per GPU |
| Scale-out | ConnectX-7 · 400 Gb/s (~3.2 Tb/s/node) |
| Cooling | Air (6U–10U) or liquid (4U–5U), by integrator |
| Integrators | Lenovo · Dell · Supermicro · Gigabyte |
Memory & bandwidth (VRAM)
Each B200 GPU in the HGX B200 carries 180 GB of HBM3e — the on-package GPU memory (VRAM) available to the model. Across the 8-GPU baseboard that is 1,440 GB of HBM3e per node, pooled and addressable over NVLink so a large model and its long-context KV cache can span all eight GPUs.
Memory bandwidth is roughly ~8 TB/s per GPU (derived from the ~64 TB/s aggregate per-node figure the integrators publish, divided across eight GPUs — treat it as approximate), for about ~64 TB/s aggregate across the node. That combination — 1,440 GB of high-bandwidth memory fed at ~64 TB/s — is what lets the HGX B200 keep more of a frontier-scale model resident and well-fed than the prior Hopper generation.
On compute, each B200 delivers ~4.5 PFLOPS of dense FP8 and ~9 PFLOPS of dense FP4 tensor throughput — about 36 and 72 PFLOPS respectively across the 8-GPU node — with the FP4 path aimed at high-throughput inference. All figures are dense; NVIDIA’s DGX B200 datasheet quotes the node totals "with sparsity" (72 PFLOPS FP8 / 144 PFLOPS FP4), i.e. 2× the dense figures. (The GB200 Grace-Blackwell superchip runs a higher clock bin at ~5 / ~10 PFLOPS dense per GPU.)
NVLink & scale-out
Inside the node, the eight B200 GPUs are wired over a fifth-generation NVLink baseboard at 1.8 TB/s per GPU — double the per-GPU NVLink bandwidth of the Hopper generation — giving all-to-all connectivity across the 8-GPU domain with minimal communication overhead.
To scale beyond a single node, the HGX B200 uses NVIDIA ConnectX-7 adapters at 400 Gb/s each with GPUDirect — eight per node, for roughly ~3.2 Tb/s of scale-out bandwidth per node on InfiniBand or Ethernet fabrics. (Supermicro also offers a higher-bandwidth ConnectX-8 build on its liquid-cooled 4U variant.) NVLink handles the dense traffic inside the node; ConnectX stitches many nodes into a larger training cluster.
Cooling & form factor
The HGX B200 ships in two thermal designs, and the choice drives the form factor:
- Air-cooled (6U–10U). The mainstream build — the Dell PowerEdge XE9680 at 6U, the Supermicro 8U, and the Gigabyte 10U chassis — drops into standard data-center racks with no liquid loop, the fastest facilities fit.
- Liquid-cooled (4U–5U). A denser, direct-to-chip liquid build — the Dell XE9685L and Supermicro’s DLC variant at 4U, or the Lenovo ThinkSystem SR780a V3 at 5U with Neptune cooling — packs the same 8 GPUs into fewer rack units for high-density deployments, but needs a cooling loop or CDU.
The air-vs-liquid trade-off is the same one that governs the Hopper HGX H100 (see HGX H100 air vs liquid cooling): liquid buys density at the cost of facility water and plumbing, while air is simpler to deploy. Both carry the identical GPU, memory, and NVLink specs — only density and facility requirements differ.
Available integrators
The HGX B200 ships as a factory-integrated 8-GPU node from several OEMs — Lenovo (ThinkSystem SR780a V3), Dell (PowerEdge XE9680 / XE9685L), Supermicro, and Gigabyte — each with its own chassis, cooling, host CPU, and support model. All are new and factory-integrated: the GPU, memory, and NVLink specifications are common across builds, while chassis, cooling, host CPU, warranty, and lead time differ by integrator. Each build below links to its full specification.
Supermicro
Supermicro 8-GPU
NVIDIA HGX B200 8-GPU Blackwell server — 1,440 GB HBM3e per node on Supermicro’s 8U air-cooled platform, with a direct-liquid-cooled 4U build also available.
Dell
Dell PowerEdge XE9680 / XE9685L
NVIDIA HGX B200 8-GPU Blackwell server — 1,440 GB HBM3e per node on the air-cooled Dell PowerEdge XE9680, with a direct-liquid-cooled XE9685L build also available.
Gigabyte
Gigabyte 8-GPU
NVIDIA HGX B200 8-GPU Blackwell server — Gigabyte’s air-cooled 8-GPU node with 1,440 GB HBM3e and 64 TB/s of aggregate bandwidth.
Lenovo
Lenovo ThinkSystem SR780a V3
NVIDIA HGX B200 8-GPU Blackwell server — 1,440 GB HBM3e per node on the Lenovo ThinkSystem SR780a V3 with Lenovo Neptune liquid cooling.
Procurement
Every HGX B200 build is quoted per configuration on request — the figure depends on integrator, cooling (air 8U vs liquid 4U), host CPU, networking, and quantity. Lead times run from ready-to-ship to a few weeks by integrator, confirmed at quote. Tell us the build you are standing up and we will return pricing, availability, and a facility-fit review. Browse the GPU catalog to compare integrations, or see how the B200 stacks up against the Hopper HGX H200.
Frequently asked questions
How much memory (VRAM) does an HGX B200 have?
Each B200 GPU in the HGX B200 carries 180 GB of HBM3e, so a full 8-GPU node holds 1,440 GB of HBM3e — pooled and addressable across the GPUs over fifth-generation NVLink, with roughly ~64 TB/s of aggregate memory bandwidth.
How many GPUs are in an HGX B200 node?
An HGX B200 node has 8 NVIDIA B200 (Blackwell) GPUs on a single fifth-generation NVLink baseboard, connected all-to-all at 1.8 TB/s per GPU.
What is the HGX B200’s power consumption?
The HGX B200 is a high-density Blackwell node, so it draws substantial per-node power — but the exact figure depends on the integrator build, host CPU, and whether it is the air-cooled 8U or liquid-cooled 4U configuration. Plan for a high-density deployment and confirm the precise per-node power draw at quote.
How much does an HGX B200 server cost?
The HGX B200 is quoted per configuration on request — the figure depends on integrator, cooling, host CPU, and networking. Tell us the build you need and we will return pricing and availability.