AMD Instinct MI300X Specs & Datasheet (8-GPU Server)
TL;DR
The AMD Instinct MI300X is AMD’s CDNA 3 data-center accelerator: 192 GB of HBM3 per GPU at 5.3 TB/s of bandwidth, deployed as an 8-GPU OAM node holding 1,536 GB of pooled memory. At 750 W per accelerator it is the most deployable member of the Instinct line — air-cooled 8-GPU builds ship from Supermicro and Dell without any facility-water requirement. Configuration, power, and pricing are confirmed at quote.
On this page
What the MI300X is
The AMD Instinct MI300X is AMD’s CDNA 3 data-center accelerator, and the part that established the Instinct line as a credible alternative for memory-bound AI work. Each accelerator carries 192 GB of HBM3 at roughly 5.3 TB/s of bandwidth.
Like NVIDIA’s HGX platforms, the MI300X is sold as a node, not a card. Eight accelerators sit on an OAM/UBB baseboard connected by AMD Infinity Fabric, giving 1,536 GB of pooled HBM3 in one chassis. Its successors keep the same shape: the MI325X adds memory and bandwidth on the identical CDNA 3 compute core, and the CDNA 4 MI355X is the current flagship.
What keeps the MI300X relevant is deployability. At 750 W per accelerator it runs air-cooled in a standard rack — no cold plates, no CDU, no building water loop. For a buyer who needs large pooled memory but does not have a liquid-cooled facility, that is frequently the deciding factor.
Full spec sheet
The MI300X per-GPU and 8-GPU node specification. The accelerator, memory, and fabric figures are fixed characteristics of the platform; chassis, host CPU, cooling, site power draw, and final configuration vary by build and are confirmed at quote.
| Spec | AMD Instinct MI300X |
|---|---|
| Architecture | AMD Instinct MI300X · CDNA 3 |
| Form factor | OAM · 8-GPU node |
| HBM3 per GPU | 192 GB |
| HBM3 per 8-GPU node | 1,536 GB |
| Memory bandwidth | 5.3 TB/s per GPU |
| Dense FP16 / BF16 | ~1,307.4 TFLOPS (~1.31 PFLOPS) per GPU |
| Dense FP8 | ~2,614.9 TFLOPS (~2.61 PFLOPS) per GPU |
| Dense FP16 (8-GPU node) | ~10.5 PFLOPS |
| Dense FP8 (8-GPU node) | ~20.9 PFLOPS |
| FP4 | Not supported (CDNA 3) |
| GPU interconnect | AMD Infinity Fabric · 896 GB/s |
| GPU TDP | 750 W per GPU |
| Cooling | Air-cooled |
| Integrators | Supermicro, Dell |
Memory & bandwidth
Each MI300X carries 192 GB of HBM3 at about 5.3 TB/s, so an 8-GPU node pools 1,536 GB of high-bandwidth memory addressable over Infinity Fabric.
That capacity is the reason to look at the part. A single MI300X holds a model that would otherwise have to be sharded across several 80 GB GPUs — and sharding costs both latency and engineering time. For memory-bound work — large models held resident, long-context inference with a big KV cache — capacity per GPU is frequently the binding constraint rather than raw FLOPS.
Against its own line, the MI300X gives up memory to its successors: the MI325X carries 256 GB at 6.0 TB/s and the MI355X 288 GB at 8 TB/s. What the MI300X gives back is a lower power envelope and the widest air-cooled availability.
Compute
Each MI300X delivers roughly ~1,307.4 TFLOPS (~1.31 PFLOPS) of dense FP16/BF16 and ~2,614.9 TFLOPS (~2.61 PFLOPS) of dense FP8. Across an 8-GPU node that is about ~10.5 PFLOPS dense FP16 and ~20.9 PFLOPS dense FP8.
Those figures are identical to the MI325X — the two parts share the same CDNA 3 compute core, and the MI325X’s generational gain is memory and bandwidth, not FLOPS. CDNA 3 has no FP4 datatype; that arrives with CDNA 4 on the MI355X, which roughly doubles dense FP16 and FP8 as well. All numbers here are dense; AMD’s datasheet headline figures double them with 2:4 sparsity.
Infinity Fabric & scale-out
Inside the node, the eight accelerators communicate over AMD Infinity Fabric at 896 GB/s. This is the on-baseboard fabric that lets the eight GPUs share their 1,536 GB of pooled HBM3 as one node, rather than eight isolated cards.
For scale-out beyond the node, shipping builds pair each GPU with a 400 Gb/s InfiniBand or RoCE NIC. The practical consequence: the MI300X is deployed as a node-scale unit — where 1,536 GB of pooled memory in one chassis does the work — and there is no AMD equivalent to a rack-scale NVLink domain like the GB200 NVL72. Exact NIC count and fabric tier are specified per build.
Power & cooling
Each MI300X has a 750 W TDP, so an 8-GPU baseboard draws on the order of 6 kW from the accelerators alone, before host CPUs, system memory, and conversion losses.
That is the MI300X’s quiet advantage. Six kilowatts of accelerator load is a load a conventional air-cooled rack can carry, which is why both shipping integrations are air-cooled: Supermicro’s 8U AS-8125GS-TNMR2 and Dell’s 6U PowerEdge XE9680. Neither needs facility water or a CDU.
By contrast the CDNA 4 MI355X runs at 1,400 W per accelerator — roughly 11.2 kW per baseboard — and is a direct-to-chip liquid build that will not deploy without a building water loop. If a site cannot take liquid, that difference decides the part. Exact per-node draw and facility fit depend on the configuration and are confirmed at quote.
MI300X vs MI325X and MI355X
Where the MI300X sits in the AMD Instinct line. The MI325X shares its CDNA 3 compute core and adds memory and bandwidth; the MI355X is the CDNA 4 successor.
| Spec | MI300X | MI325X | MI355X |
|---|---|---|---|
| Architecture | CDNA 3 | CDNA 3 | CDNA 4 |
| HBM per GPU | 192 GB HBM3 | 256 GB HBM3e | 288 GB HBM3E |
| HBM per 8-GPU node | 1,536 GB | 2,048 GB | 2,304 GB |
| Memory bandwidth | 5.3 TB/s | 6.0 TB/s | 8 TB/s |
| Dense FP16 | ~1.31 PFLOPS | ~1.31 PFLOPS | ~2.5 PFLOPS |
| Dense FP8 | ~2.61 PFLOPS | ~2.61 PFLOPS | ~5 PFLOPS |
| Dense FP4 | Not supported | Not supported | ~10.1 PFLOPS |
| GPU TDP | 750 W | 1,000 W | 1,400 W |
| Cooling | Air | Air | Direct-to-chip liquid |
Available integrators
The MI300X ships as a factory-integrated 8-GPU node. The accelerator, memory, and fabric specifications are fixed; chassis, host CPU, cooling, warranty, and lead time depend on the build.
Supermicro
Supermicro AS-8125GS-TNMR2
AMD Instinct MI300X 8-GPU server — 1,536 GB HBM3 per node on the Supermicro AS-8125GS-TNMR2 (8U air-cooled) with dual AMD EPYC CPUs.
Dell
Dell PowerEdge XE9680
AMD Instinct MI300X 8-GPU server — 1,536 GB HBM3 per node on the air-cooled Dell PowerEdge XE9680, with 192 GB per GPU for large memory-bound inference.
What drives the price of an MI300X server
An 8-GPU MI300X server is quoted per configuration on request — there is no meaningful list price, because two nodes with the same eight accelerators can differ substantially in cost. The variables that actually move the number:
- Accelerator count. The 8-GPU baseboard is the standard unit of sale; the accelerators dominate the bill of materials.
- Integrator and chassis. The 8U Supermicro build versus the 6U Dell PowerEdge XE9680 — rack units, serviceability, and support model differ.
- Host CPU and memory. The host CPU tier (EPYC, or Xeon on the Dell) and the system DDR5 capacity feeding the accelerators.
- Scale-out networking. How many 400 Gb/s InfiniBand or RoCE NICs per node, and the switching to match.
- Quantity and support scope. Single node versus a multi-rack cluster, and the warranty and on-site service term.
- Lead time. What you need delivered, and when.
For the wider picture of how accelerator servers are actually quoted, see NVIDIA GPU server pricing. Tell us the build you are standing up and we will return pricing, availability, and a facility-fit review. Browse the GPU catalog to compare integrations.
Frequently asked questions
What are the AMD Instinct MI300X specs?
The MI300X is an AMD CDNA 3 accelerator with 192 GB of HBM3 per GPU at 5.3 TB/s of bandwidth, ~1,307.4 TFLOPS (~1.31 PFLOPS) of dense FP16/BF16 and ~2,614.9 TFLOPS (~2.61 PFLOPS) of dense FP8, and a 750 W TDP. It ships as an 8-GPU OAM node connected by AMD Infinity Fabric at 896 GB/s, pooling 1,536 GB of HBM3.
How much memory does the MI300X have?
Each MI300X carries 192 GB of HBM3 at roughly 5.3 TB/s of bandwidth. An 8-GPU node therefore pools 1,536 GB of high-bandwidth memory over AMD Infinity Fabric — enough to hold a model resident that would otherwise have to be sharded across several 80 GB GPUs.
How does the MI300X compare to the MI325X and MI355X?
The MI300X and MI325X share the same CDNA 3 compute core, so their dense FP16 (~1.31 PFLOPS) and FP8 (~2.61 PFLOPS) per-GPU throughput match; the MI325X adds memory and bandwidth (256 GB at 6.0 TB/s versus 192 GB at 5.3 TB/s). The CDNA 4 MI355X roughly doubles compute (~2.5 PFLOPS dense FP16, ~5 PFLOPS dense FP8), adds FP4, and carries 288 GB at 8 TB/s — but at 1,400 W it requires direct-to-chip liquid cooling, where the MI300X runs air-cooled at 750 W.
Is the MI300X air-cooled?
Yes. At 750 W per accelerator the MI300X ships in air-cooled 8-GPU nodes — Supermicro’s 8U AS-8125GS-TNMR2 and Dell’s 6U PowerEdge XE9680 — with no facility water or CDU requirement. That is its main deployment advantage over the 1,400 W liquid-cooled MI355X.
Does the MI300X support FP4?
No. FP4 is a CDNA 4 datatype and arrives with the MI355X. The MI300X and MI325X are CDNA 3 and support FP8 and FP16/BF16, at ~2.61 PFLOPS and ~1.31 PFLOPS dense per GPU respectively.
How much does an 8-GPU MI300X server cost?
It is quoted per configuration on request. The figure depends on accelerator count, integrator and chassis, host CPU tier, system memory, how many 400 Gb/s scale-out NICs, quantity, support scope, and lead time. Tell us the build you need and we will return pricing and availability.
Related