Pantheon

GE Vernova

GE LM6000 PD SPRINT (DLE) Cogeneration Plant — 46–48 MW + 50–55 t/h HRSG

Used and surplus GE LM6000 PD SPRINT DLE cogeneration plant for sale — a complete 46–48 MW combined-heat-and-power block with a 50–55 t/h heat-recovery steam generator, an exchanged factory-refurbished engine at 28,000–32,000 hours, measured performance and accredited emissions data.

Available
GE Vernova
Aeroderivative
LM6000-class
Fast-start
Natural gas
Condition: Used and surplus. Lead time: on order placement (dismantling and export scoped per site).Request a quote →

Used and surplus GE LM6000 PD SPRINT cogeneration plant with Dry Low Emissions (DLE) combustion available for sale through Pantheon — a complete plant rather than a bare generating set. The scope comprises the LM6000 PD SPRINT gas turbine, generator and load gearbox, a heat-recovery steam generator rated at 50–55 tonnes per hour of high-pressure steam, natural-gas booster compression, a distributed control system with modern turbine controls and vibration monitoring, generator switchgear, and a spares inventory included in the sale. The plant was commissioned in 2010–2013; in 2020–2022 the complete engine was exchanged for a factory-refurbished unit, documented in an OEM removal-and-installation report, and that engine now carries 28,000–32,000 hours. Per OEM guidance the next major event falls at 50,000 engine hours — about 20,000 hours of runway — and is a hot-section exchange with a minor generator inspection, not a full major overhaul. The headline package hours are far higher; the engine figure is the one that describes remaining life. Performance is measured, not asserted: an OEM test-cell report after that engine’s overhaul recorded corrected sprinted gross output of 46–47 MW at a heat rate of 8,400–8,700 Btu/kWh, within guarantee tolerance, and an independent accredited stack test from the last 18 months returned NOx and CO comfortably inside consent against a ≤25 ppmvd design basis — useful documents for a buyer facing a permitting process. Three open items from the most recent inspection — one hot-section follow-up and two component replacements — are disclosed in full at quote; one booster compressor is high-hours and should be treated as a replacement item; the OEM service agreement has lapsed and a buyer would negotiate a new one. The plant was laid up in 2024–2025 and is stored to OEM recommendation. Dismantling and export from site is a substantial exercise and should be scoped early. Exact rating, hours, and configuration confirmed at quote.

Specifications

TypeComplete cogeneration plant · LM6000 PD SPRINT aeroderivative gas turbine
Output (electrical)46–48 MW nameplate · 46–47 MW corrected sprinted gross on OEM test cell
Heat rate (measured)8,400–8,700 Btu/kWh on OEM test cell, within guarantee tolerance
SteamHRSG rated 50–55 t/h high-pressure steam
CombustorDLE (dry low emissions) · design basis ≤25 ppmvd NOx and CO at 15% O₂
Emissions (measured)Independent accredited stack test within the last 18 months · NOx and CO well inside consent limits
SPRINTSpray intercooling · holds rated output on hot days
Balance of plantGenerator · load gearbox · gas booster compression · DCS · vibration monitoring · switchgear · spares
FuelNatural gas
Engine historyPlant commissioned 2010–2013 · complete engine exchanged 2020–2022 for a factory-refurbished unit
Operating hours28,000–32,000 engine hours · next major event at 50,000 h is a hot-section exchange, not a major overhaul
DocumentationOEM engine-exchange report · test-cell performance · borescope + semi-annual inspections · controls, compressor-cleaning and emissions reports · spares inventory · lifting and shipping drawings
Open itemsThree from the latest inspection (one hot-section follow-up, two component replacements) · one high-hours booster compressor — full list at quote
DeliveryOn order placement · dismantling and export to be scoped early
Offer windowLot listed through 2026-12-31 · availability re-confirmed at quote
ConditionUsed and surplus · laid up 2024–2025, stored to OEM recommendation

Specifications shown are headline figures. Confirm full configuration details when you request a quote.